Flow Conditions
All six flow-condition fields are required. Enter your temperatures; 40°F is a suggested default, not an entered value.
Ambient / Bath
Burner capacity and preliminary dimensions are calculated automatically from the heating duty, efficiency, coil selection, and allowable wall heat flux.
Awaiting required flow conditions.
Automatic sizing basis & limits
Shell length: coil-required straight length plus 18 in total clearance and return-bend projections, rounded up to 6 in. Firetube: smallest listed even NPS (4–24) meeting the bath-duty / allowable-flux area within that length. Burner capacity equals calculated firing input, including efficiency; no additional hidden burner margin is applied. Shell: fit the coil and both firetube legs, then round up to the next even NPS.
Envelope assumptions: 1/4 in shell wall; 1 in side and coil-to-firetube clearance; 1.5 in top clearance; 1.25D coil pitch; 1.5D firetube return radius. Firetube return area is excluded conservatively. Coil routing, supports, actual shell wall, firetube wall/clear bore, flame length, heat-release limits and draft must be reviewed by the burner supplier and fabricator. These are not certified dimensions.
Coil Selection
Duty & Firing
Coil
Firetube & Shell
Flange Check
Bill of Materials — Preliminary Spec
Need a complete package? Carry this heater specification into Fuel Train Wizard, select the BMS there, and submit one combined quote request. Contact details are collected only when you request a quote.